In-Line Ultrasonic Monitoring for Sediments Stuck on Inner Wall of a Polyvinyl Chloride Pipe
http://www.hindawi.com/journals/tswj/2014/731621/
The Scientific World Journal
Volume 2014 (2014), Article ID 731621, 8 pages
http://dx.doi.org/10.1155/2014/731621
In-Line Ultrasonic Monitoring for Sediments Stuck on Inner Wall of a Polyvinyl Chloride Pipe
1Department of Mechanical Convergence Engineering, Hanyang University, Seoul 133-791, Republic of Korea
2School of Mechanical Engineering, Hanyang University, Seoul 133-791, Republic of Korea
Received 28 March 2014; Accepted 2 July 2014; Published 28 August 2014
Academic Editor: Ying Lei
Abstract
This research verified the applicability and effectiveness of the ultrasonic monitoring of sediments stuck on the inner wall of polyvinyl chloride (PVC) pipes. For identifying the transmittance of acoustic energy and the speed of sound in the PVC material, the pulse-echo ultrasonic testing was conducted for PVC sheets of different thicknesses. To simulate the solidified sediment, the hot melt adhesive (HMA) was covered on the inner wall of the PVC pipe in different heights. From the experiment, the speeds of sound in the PVC and the HMA materials were obtained as about 2258 and 2000 m/s, respectively. The thickness of the materials was calculated through the signal processing such as taking the absolute value and low pass filtering, the echo detection, and the measurement of the time of flight. The errors between actual and measured thicknesses of PVC sheets were below 5%. In the case of the substance stuck on the inner wall, the errors were below 2.5%. Since the pulse-echo ultrasonic inspection is available on the outer surface and its measurement accuracy was over 95%, it can be an efficient and effective in-service structural health monitoring for the sediment on the wall of PVC pipes.
-
Influence of slit width on harmonic generation in ultrasonic surface waves excited by masking a laser beam with a line arrayed slit
-
Evaluation of Ultrasonic Nonlinear Characteristics in Heat-Treated Aluminum Alloy
-
Initial Second Harmonic Generation in Narrowband Surface Waves by Multi-Line Laser Beams for Two Kinds of Spatial Energy Profile
-
Feasibility of MFC (Macro-Fiber Composite) Transducers for Guided Wave Technique
-
Imaging of contact acoustic nonlinearity using synthetic aperture technique
-
Thermal Damage Characterization of Silicon Wafer Subjected to CW Laser Beam
-
Application of Macrofiber Composite for Smart Transducer of Lamb Wave Inspection
-
Evaluation of Ultrasonic Nonlinear Characteristics in Heat-Treated Aluminum Alloy (Al-Mg-Si-Cu)
-
Crack Detection in Single-Crystalline Silicon Wafer Using Laser Generated Lamb Wave
-
A6061 합금의 석출경화 열처리에 따른 탄성파의 음향 특성 연구
-
Evaluation of Ultrasonic Nonlinear Characteristics in Heat-Treated Aluminum Alloy
-
Initial Second Harmonic Generation in Narrowband Surface Waves by Multi-Line Laser Beams for Two Kinds of Spatial Energy Profile Models
-
Feasibility of MFC (Macro-Fiber Composite) Transducers for Guided Wave Technique
-
Thermal damages on the surface of a silicon wafer induced by a near-infrared laser
-
Slip damage of silicon wafers subjected to continuous infrared laser irradiation
-
Simulations for Internal Defect Inspection using Laser Generated Ultrasonic Wave in Ablation Regime
-
Evaluation of Ultrasonic Nonlinear Characteristics in Artificially Aged Al6061-T6
-
Initiation time of near-infrared laser-induced slip on the surface of silicon wafers
-
In situ detection of laser-induced slip initiation on the silicon wafer surface
-
In-Line Ultrasonic Monitoring for Sediments Stuck on Inner Wall of a Polyvinyl Chloride Pipe